Biomechanical Rationale for Osteosynthesis Stability in Lower Limb Long Bone Fractures Under Multi-directional Loading: A Finite Element Analysis

Abstract

Background. In the general structure of trauma, fractures of the bones of the lower extremities account for 47.3%, among which diaphyseal injuries occupy the leading place. The choice of the optimal type of fixator (osseous, intramedullary, or external) remains a subject of discussion, since the stability of the “bone – implant” system directly determines the nature of the regenerative process and the timing of consolidation. Objective: based on three-dimensional mathematical modeling using the finite element method, to conduct a comparative analysis of the stress-strain state of femur and tibia models with fractures at different diaphyseal levels under four variants of multidirectional loads when using four common osteosynthesis systems.

Description

Citation

Hryhoruk V, Rysovana L, Makarov V, Karpinsky M. Biomechanical Rationale for Osteosynthesis Stability in Lower Limb Long Bone Fractures Under Multi-directional Loading: A Finite Element Analysis. Medicina Moderna. 2026;33(3):283-11. Available from: https://doi.org/10.31689/rmm.2026.33.3.283

Endorsement

Review

Supplemented By

Referenced By