Method for measuring X-ray reflections of microelements of inorganic compounds in soft tissues
dc.contributor.author | Mikhailov, I. | |
dc.contributor.author | Negoduyko, Volodymyr | |
dc.contributor.author | Mikhaylusov, R. | |
dc.contributor.author | Mikhailov, A. | |
dc.contributor.author | Borisova, S. | |
dc.date.accessioned | 2023-11-03T14:18:06Z | |
dc.date.available | 2023-11-03T14:18:06Z | |
dc.date.issued | 2023-07-25 | |
dc.description.abstract | An alternative method is proposed for measuring X-ray diffraction peaks from micro-impurities of inorganic phases in soft tissues. Unlike traditional XRD, each of the diffraction peaks corresponding to the interplanar spacing di , is measured using radiation with a wavelength of λi →2di . This makes it possible to register diffraction peaks at large θ angles, thereby increasing the angular resolution ∼tanθ. This approach made it possible to increase the beam angular divergence ∆θ from 0.05° (for standard XRD) to 3°, gain ∼(∆θ) 2 in the spectrometer luminosity, and reduce ∼(∆θ) -2 radiation load per unit area of soft tissue. A criterion for choosing the wavelength and beam divergence based on the micro-impurity structure is proposed. The results of measuring the diffraction peaks of micro-impurities of iron oxides in soft tissues damaged by a fragment wound are presented. The excess iron content in damaged tissues was certified by the XRF method with calibration using standard samples and did not exceed 0.4 mass%. Measurements of the main diffraction peaks of iron oxides Fe2 O3 , d=2.69Å, as well as Fe3 O4 , d=1.61Å and FeO(OH), d=1.71Å, were carried out in Cl- Кα ( . λ = 4 728 ) and Sc-Кα ( λ = 3. ) 031 , respectively. We used the scheme of a portable EDXRF spectrometer with a secondary KCl-Sc target and an angular beam divergence of ∆θ≈3°. Without radiation damage to soft tissues, the detection limits were reached: 0.12 mass% for Fe2 O3 , 0.059 mass% for Fe3 O4 and 0.034 mass% for FeO(OH) | en_US |
dc.identifier.citation | Method for measuring X-ray reflections of microelements of inorganic compounds in soft tissues / I. F. Mikhailov, V. V. Negoduyko, R. M. Mikhaylusov, A. I. Mikhailov, S. S. Borisova // Functional materials. ─ 2023. ─ № 30 (3). ─ P. 447─452. | en_US |
dc.identifier.uri | https://repo.knmu.edu.ua/handle/123456789/32753 | |
dc.language.iso | en | en_US |
dc.subject | X-ray diffraction | en_US |
dc.subject | micro-impurities | en_US |
dc.subject | soft tissues | en_US |
dc.subject | EDXRF spectrometer | en_US |
dc.subject | secondary target | en_US |
dc.subject | 2023a | en_US |
dc.title | Method for measuring X-ray reflections of microelements of inorganic compounds in soft tissues | en_US |
dc.title.alternative | Спосіб вимірювання рентгенівських відбиттів мікроелементів неорганічних сполук у м’яких тканинах | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Method for measuring X-ray reflections.pdf
- Size:
- 2.7 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 11.22 KB
- Format:
- Item-specific license agreed upon to submission
- Description: