Assessment of accuracy and applicability of PiCCO in circulating blood volume management: a clinician’s perspective

dc.contributor.authorBelousov, Andriy
dc.date.accessioned2026-10-21T17:29:51Z
dc.date.issued2026
dc.description.abstractMonitoring with the PiCCO technology (Pulse Contour Cardiac Output) has become a widely adopted method for hemodynamic assessment and fluid management in critically ill patients. The technique combines transpulmonary thermodilution and pulse contour analysis to provide continuous or intermittent measurements of cardiac output, global end-diastolic volume index (GEDVI), extravascular lung water index (EVLWI), and systemic vascular resistance index (SVRI). Despite its technological sophistication and broad clinical use, the validity, reproducibility, and universal applicability of PiCCO-derived data remain subject to ongoing debate. Particular concern arises in clinical scenarios involving altered physicochemical properties of blood, vascular dysregulation, vasoplegia, or hypoproteinemia, where thermodilution-based calculations may become inaccurate. Furthermore, neurohumoral and reflex circulatory mechanisms - such as the Schwik-Larin reflex - are not accounted for in the PiCCO model, yet may significantly impact hemodynamic dynamics and confound interpretation. This review provides a critical analysis of the methodological, physiological, and clinical limitations of PiCCO monitoring. Special emphasis is placed on the influence of blood rheology, temperature, microcirculatory changes, and endothelial dysfunction on the reliability of computed hemodynamic variables. The necessity of an integrative approach to data interpretation is emphasized, involving the correlation of PiCCO-derived parameters with the clinical picture, laboratory findings, therapeutic response, and the patient's pathophysiological status. In conclusion, PiCCO remains a potentially valuable tool in critical care; however, its effective use requires clinical vigilance, awareness of physiological constraints, and individualized therapeutic decision-making, particularly in fluid management strategies.
dc.identifier.citationBelousov A. Assessment of accuracy and applicability of PiCCO in circulating blood volume management: a clinician’s perspective. Clinical research and clinical reports. 2026;9(1):4 p. doi:10.31579/2835-8325/191
dc.identifier.urihttps://repo.knmu.edu.ua/handle/123456789/38618
dc.language.isoen
dc.subjectPiCCO
dc.subjecthemodynamic monitoring
dc.subjecttranspulmonary thermodilution
dc.subjectcritical care
dc.subjectvascular tone
dc.subjectblood rheology
dc.subjectpathophysiological interpretation
dc.subject2026а
dc.titleAssessment of accuracy and applicability of PiCCO in circulating blood volume management: a clinician’s perspective
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Assessment of accuracy and applicability of PiCCO in circulating blood volume management.pdf
Size:
410.29 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
11.22 KB
Format:
Item-specific license agreed upon to submission
Description: