Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repo.knmu.edu.ua/handle/123456789/20308
Назва: Human Red Blood Cell Properties and Sedimentation Rate: a Biomechanical Study
Автори: Kizilova, Nataliya
Batyuk, Liliya
Cherevko, Vitalina
Теми: red blood cells
biomechanics
electric potential
medical diagnostics
sedimentation rate
Дата публікації: 7-вер-2018
Видавництво: Springer International Publishing
Бібліографічний опис: Kizilova N. Human Red Blood Cell Properties and Sedimentation Rate: a Biomechanical Study / N. Kizilova, L. Batyuk, V. Cherevko // Biomechanics in Medicine and Biology : Proceedings of the International Conference of the Polish Society of Biomechanics, Zielona Gora, Poland, September 5–7, 2018 / K. Arkusz, R. Bedzinski, T. Klekiel, S. Piszczatowski, eds. – 2019. – P. 3–22. – (Springer Series «Advances in Intelligent Systems and Computing», Vol.831). – DOI: doi.org/10.1007/978-3-319-97286-2_1.
Короткий огляд (реферат): Human blood is widely used for clinical diagnostics due to its easy accessibility and high sensitivity for any metabolic disorders and diseases. In the paper different mechanical and electric properties of red blood cells (RBC) useful for diagnostics are discussed. The experimental data on the erythrocyte sedimentation rate (ESR) test in its standard procedure and continuous computer assisted assessment are presented. The review of mathematical approaches for reasonable ESR estimation is given. The continuous model of blood as three phase suspension is used for numerical estimation of aggregate ability of RBC. The problem on RBC aggregation and sedimentation in a thin vertical tube is considered. A numerical solution of the formulated hyperbolic problem is obtained by the method of characteristics. Numerical computations have been carried out for a wide range of RBC parameters proper to healthy state and patients with cancer, drug and food allergy. It is shown the continuous sedimentation curves give more diagnostic information than the standard ESR value. Based on the experimental and theoretical study, a biomechanical interpretation of the ESR curves is proposed.
URI (Уніфікований ідентифікатор ресурсу): https://repo.knmu.edu.ua/handle/123456789/20308
Розташовується у зібраннях:Наукові праці. Кафедра медичної та біологічної фізики і медичної інформатики

Файли цього матеріалу:
Файл Опис РозмірФормат 
Human_Red_Blood_Cell_Propert_Sedimen_Rate_Biomech_Study.pdf1,24 MBAdobe PDFЕскіз
Переглянути/відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.